TANK and TANKLESS HOT WATER CIRCULATOR

EASY 1 - 2 - 3 INSTALL

(Connect sinks HW hoses to E + F and CW hoses to G + H)

 

We identified the industries need for greener-efficient hot water circulators with install flexibility and control customization capable of satisfying even complex lifestyles. Placing efficiency and comfort first, and foremost combined with over 20 years experience engineering hot water circulators, we achieved our goals. In addition to providing consumers with twice the convenience of other hot water circulators our proprietary controller offers "on-the-fly" comfort temperature optimization. Consumers wanting hotter hot water instantly out their taps simply turn the temperature dial clockwise or counter clockwise to lower the temperature. After only a few adjustments, homeowners will have optimized their hot water system's comfort and readiness. Readytemp homeowners benefit from an optimized hot water lifestyle with unmatched comfort, convenience and water savings.

 

Engineering Tactic / Benefit

 

 All systems include a Digital Timer / 20 Events
(built-in 30 day backup battery; eliminates standby energy consumption as well as time corrections / reprogramming after a power outage)


                                                        CLICK FOR LARGER VIEWING  

       

   TL4000's Pump Data     TL-Series Install / User Guide      TL5000's Pump Data

 

A - CONTROL ENABLER SOCKET  (3-Prong Wall Socket) accepts 2 and 3-prong control devices for unlimited control customization.

B - CONTROL ENABLER PLUG (2-Prong Plug) plugs into ANY control device plugged into (A).  If (B) directly to (A) 24 hr cyclic operation, leave unplugged for on-demand only.
C - ON-DEMAND / SINGLE-CYCLE RJ11 PHONE JACK.  ANYTIME single-cycle operation / scheduled-off overrides, using 1 or more doorbell buttons wired to phone cords

D - TEMPERATURE ADJUSTMENT DIAL optimizes comfort and savings. Range 40°F to 118°F non-limiting

E, F - HOT WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing HW hose and connect

G, H - COLD WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing CW hose and connect

I, J - PUMP ISOLATION SHUT-OFF VALVES Fulfills US WaterSense requirements, convenient pump access and a means to manipulate flow rate

K - MAIN POWER CORD DETACHABLE PLUG-IN  Provides power to system.

L - STAINLESS STEEL TEMPERATURE PROBE  For "accurate" water contacting temperature sensing for 0.5F deg. adjustment accuracy

M - SILENT ACTION "NORMALLY CLOSED" HW SOLENOID VALVE  Prevents HWL siphoning into CWL during CW use. Opens only during active pumping cycle.

 

DISCOVER ReadyTemp®'s USER FRIENDLY CONTROL / ACTIVATION and WIRELESS OPTIONS

 

HEAD PRESSURE is a pump's ability to move a 1" column of water vertically upwards in a pipe. This being said a TL4000 system would be inadequate in pushing water up to a third floor since it's rated to 16' of head. The TL5000 system would be the better fit.

 

OPEN LOOP SYSTEM / MODEL DESIGNATOR "N"

COLD LINE USED AS RETURN

 

Homes with  NO DEDICATED hot water return line OPEN-LOOP systems use Cold Water line as return line

     TL4000N Small - Med size home Flow 1-14 gpm / 16' head

     TL5000N Large size home Flow 1-28 gpm / 30' head

 

INSTALL TYPE         LOCATION

     COMMON        Pump UNDER SINK connect as follows:

                             E and F - hot supply and hot faucet (interchangeable / either one)

                             H and G - cold supply or cold faucet (interchangeable / either one)

        

   ALTERNATE      Pump AT WATER HEATER or ON HW LINE REQUIRES ASSEMBLING (SWING CHECK VALVE, TEMP PROBE and SOLENOID)

                                Requires running 5 wires (2 = temp probe, 3 = solenoid 18 AWG) from control box to by-pass assembly connect wires to temperature probe and solenoid valve wires.

                     Using appropriate fittings In series connect (1) check valve, temperature probe and solenoid valve, install between hot and cold pipes anywhere near end of line.

 

 

 

 

The above illustrates that the pump can be placed most anywhere on the hot water line.  Beneficial for homes having easy access to plumbing lines in a basement, crawlspace, attic, etc.  Placing the by-pass valve assembly near the last hot water load on the loop ensures all loads on the loop are covered. This configuration is often a better choice for pedestal sinks or when space limits prevent a under sink installation. 

 

CLOSED LOOP SYSTEM / MODEL DESIGNATOR "D"

DEDICATED HOT WATER LINE (EXISTING HOT WATER LOOP)

 

Homes with  DEDICATED hot water return line CLOSED-LOOP systems use Hot Water Loop to return water back to water heater

     TL4000D Sm - Med size home Flow 1-14 gpm / 16' head

     TL5000D Large size home Flow 1-28 gpm / 30' head

 INSTALL TYPE         LOCATION

     COMMON       Pump AT WATER HEATER cold water in-let / drain spout (helps prevent sediment buildup at bottom of water heater)

                        Rotate pump head to achieve desired direction of flow (specify direction in comments area when placing order we'll do it for you, to minimize your project time)

                    Connect to flanges, install  temperature probe. (installing at last HW load on loop reduces demand on pump and water heater by eliminating repeatedly reheated end

  of loop where no loads exist.) to hot water loop.

                      

    ALTERNATE     Pump ELSEWHERE ON LOOP (for efficiency install probe just after last hot water load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

  

 

 

 

TL4000's Pump Data     TL-Series Install / User Guide      TL5000's Pump Data

 

A - CONTROL ENABLER SOCKET  (3-Prong Wall Socket) accepts 2 and 3-prong control devices for unlimited control customization.

B - CONTROL ENABLER PLUG (2-Prong Plug) plugs into ANY control device plugged into (A).  If (B) directly to (A) system is 'enabled' 24 hr temperature based cyclic operation , leave unplugged for single-cycle on-demand operation.
C - ON-DEMAND / SINGLE-CYCLE RJ11 PHONE JACK.  ANYTIME single-cycle operation / scheduled-off overrides, using 1 or more doorbell buttons(in series or individually) or momentary contact relays wired to phone cords

D - TEMPERATURE ADJUSTMENT DIAL optimizes comfort and savings. Range 40°F to 118°F non-limiting (higher temperature ranges are possible by adding resistor to temperature probe.  Call for more info if desired)

I, J - PUMP ISOLATION SHUT-OFF VALVES Fulfills US WaterSense requirements, convenient pump access and a means to manipulate flow rate if desired.

K - MAIN POWER CORD DETACHABLE PLUG-IN  Provides power to system.

L - STAINLESS STEEL TEMPERATURE PROBE  For "accurate" water contacting temperature sensing to 0.5F deg. increments.  Wire leads fitted with male / female quick connects

 

ReadyTemp®'s USER FRIENDLY CONTROL / ACTIVATION and WIRELESS OPTIONS

 

EFFICIENCY-BASED ENGINEERING

Until now, closed-loop hot water circulation system pumps installed at the water heater at the end of hot water circulation loop.  When the last hot water load on the loop is a good distance away from the water heater installing at the water heater results in significant energy waste heating pipes where no load exist.  A majority of systems don't monitor temperature and simply pump continuously based solely on time-of-day.  ReadyTemp®'s efficiency-based engineering and unique design provide a number of energy saving strategies to reduce a homes water heating energy consumption as much as 50% or more (compared with system running 24/7 w/o temp control).  ReadyTemp®'s green energy saving features include;

Implementing these features guarantees minimal demand on the homes water heater and pump operations while extending the life of the overall system.  Whatever the preference, be it hot water on-demand, scheduled, a combination of both or even continuous, ReadyTemp® is engineered with the essentials required to easily optimize system efficiency and hot water convenience.  Only ReadyTemp® offers superior flexibility in installation, activation method, activation location, comfort temperature control but, more importantly, the customization required for homeowners to live their ideal convenient hot water lifestyle. 

 

          

TL4000D / TL5000D (closed-loop models) CAN BE BUILT-TO-ORDER FITTED WITH YOUR PREFERRED FEMALE NPT THREADED FITTINGS (1/2" or 3/4") / FLOW DIRECTION (LEFT TO RIGHT / RIGHT TO LEFT)  Simply specify in the comments section when placing your order.  Default configuration is 1/2" with Right to Left flow.

 

Up to 2 story home and distance to water heater < 125'

TL4000D $435.00 Dedicated return line (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008

                                     Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,

                                     Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty

  

TL4000N $565.00 No Dedicated return line / Cold line as return (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008

                                     Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,

                                     Temperature probe,  Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty

 

Up to 3 story home and distance to water heater < 300'

TL5000D $585.00 Dedicated return line (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011   

                                     Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,

                                     Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty

 

TL5000N $720.00 No Dedicated return line / Cold line as return (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011     

                                    Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,

                                    Temperature probe,  Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty